B-Detection Plus Bauer

B-DETECTION PLUS online gas measuring system for high-pressure applications

The online gas measurement system B-DETECTION PLUS monitors the quality of the compressed air: Measurement of CO, CO2, O2 as well as optional absolute humidity and oil (VOC)1. Automatic, constantly and extremely reliable.

By means of the B-CONTROL control, you can at any time observe compliance with the limit values ​​of the breathing air standard DIN EN 12021: 20141.

In the case of an exceedance of the limit, the control system will shows an alarm on the display by means of an optical warning signal and switch off the system before air contaminated with pollutants enters the breathing air bottles.

An automatic flush valve (optional) ensures that the contaminated air is directed into the open air without interrupting the operation of the system if short-term limit values ​​are exceeded.

With the new B-DETECTION PLUS gas measuring system, you now have a reliable partner at your side, available as version B-DETECTION PLUS i integrated into the compressor, and as stand-alone version B-DETECTION PLUS s. As an operator, you can enjoy the assurance of quality and legal compliance­ with BAUER's online gas measuring system. B-DETECTION systems can easily be retrofitted to existing BAUER compressors!

(---)
P.O.R
B-DETECTION PLUS online breathing air and gas measuring systems
MEASUREMENT VALUES
  Carbon dioxide (CO2), carbon monoxide (CO), oxygen (O2), absolute humidity1, VOC1
SYSTEM LIMITATIONS
Maximum system pressure 350 bar
Maximum permissible charging rate compressor 850 l/min
Permissible operating temperature +5°C... +45°C
MEASUREMENT METHOD
CO2 Nondispersive infrared spectroscopy (NDIR)
CO, O2 electrochemical
Absolute humidity Via dew point
VOC (oil) Photoionization detector (PID)
MEASUREMENT VALUES AND MEASUREMENT ACCURACY4
CO2 0... 2.000 ppm ± 2.5 % Full scale
CO 0 … 25 ppm ± 2 % of measurement range final value
O2 0 % … 40 % O2 ± 1 % of measurement range final value
Dew-point -70 ...+60°C / 10 ... 40,000 ppm ± 2°C / 1 ppm + 20% of displayed value
VOC (oil) 0 … 1 ppm (based on isobutene as calibration gas)
FURTHER TECHNICAL SPECIFICATIONS
Operating voltage integrated: 24 VDC; stand-alone: 100-250 VAC, 50/60 Hz
Flow rate 1.0 ... 3.0 l/min
Weight integrated: 3 kg; stand-alone: 8.5 kg
Dimensions W × H × D [mm]
(with access)
integrated: 160 x 260 x 92; stand-alone: 462 x 354 x 184
SYSTEM TEST/CALIBRATION
Visual inspection and leak test Monthly
Functions check 2 Min. 3-monthly
System check 3 Annually
Calibration CO2 and PID sensor: annually and after replacing sensor; dew point sensor: every 24 months

1 Optional extra
2 Includes test with test gas; kit with test gas cylinders and pressure reducer (flow meter) available from BAUER KOMPRESSOREN
3 System check includes replacement of electrochemical sensors (CO and O2)
4 Accuracy valid at max. +/- 10 ° C deviation from calibration temperature.

    • Stock Code
      BDETEC-MAIN
    • Brand
      Bauer
No Blog available for this product.